Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :

GEFRAN Controller, Type: 600 OF“ OPEN FRAME” CONTROLLER

Update Terakhir
:
14 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
104 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail GEFRAN Controller, Type: 600 OF“ OPEN FRAME” CONTROLLER

flow control valve Controller : 600 OF“ OPEN FRAME” CONTROLLER Main features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Up to 5 outputs, relay, logic, for control, alarms • Hot/ cold function with selection of cooling liquid • 3 alarms with completely configurable function • Software alarm for load interrupt or probe in short circuit ( LBA) • Self-tuning, Auto-tuning, Soft-start, bumpless Man/ Auto function • Double set, set ramp, timed output function • Setpoint programmer functions with 3 configurable steps • Configurable internal buzzer • Optically isolated RS485 serial communication, protocol: MODBUS RTU • Self-diagnosis • Panel mounting • Screw connections with removable terminals Main applications • Small industrial ovens • Pipe welders • Temperature control units • Dryers • Climatic cells and test benches • Control panels with membrane keyboard TECHNICAL DATA INPUTS Accuracy 0, 2% f.s. ± 1digit. Sampling time 120msec. TC - Thermocouple J 0...1000° C / 32...1832° F K 0...1300° C / 32...2372° F R 0...1750° C / 32...3182° F S 0...1750° C / 32...3182° F T -200...400° C / -328...752° F custom -1999...9999 ( B, E, N, L-GOST, U, G, D, C, etc.) RTD 2/ 3 wires PT100 -200...850° C / -328...1562° F JPT100 -200...600° C / -328...1112° F PTC 990& , 25° C -55...120° C / -67...248° F NTC 1K& , 25° C -10...70° C / 14...158° F DC - Linear With scale settable from: -1999...9999 0...60mV / 12...60mV 0...10V / 2...10V 0...5V / 1...5V 0...1V / 0, 2...1V 0...20mA / 4...20mA Input impedance: Ri > 1M _ for 60mV, 1V Ri > 10K _ for 5V, 10V Ri = 50 _ for 20mA 32-segment custom linearization can be inserted. Digital input Ri = 4, 7K. ( 24V, 5mA) insulation 1500V or no-voltage contact. Function configurable for man/ auto selec- tion, local/ remote ( setpoint from serial line, setpoint1/ setpoint2; Set/ reset out- puts, start/ stop functions from tuning, software on/ off, reset alarms memory, hold. OUTPUTS 5 configurable outputs: • OUT1 available in relay or logic • OUT2, OUT3, OUT4: relay only • OUT6: logic only Freely assignable to control functions and single alarms in " OR" or " AND" . Can be slaved to front panel key or aux. digital input. Relay With contacts: 5A at 250Vac/ 30Vdc, cos_ = 1 Logic 15Vdc ± 10% ( 12V min a 30mA) Buzzer ( Output 5) Settable signal type
Tampilkan Lebih Banyak